What Is the Hardie Fire Intertenancy Wall System?
The Hardie Fire Intertenancy Wall System is a CodeMark certified, fire and acoustic rated common wall solution designed for Class 1 and 10A timber-framed buildings. A high performance, efficient lightweight wall system with a single layer design — it achieves a Fire Resistance Level (FRL) of 60/60/60 minutes and installs up to 30% faster than other comparable commonly available fire and acoustic rated wall systems in Australia.
At the core of every assembly is HardieFire™ Rock-wool Insulation — a fire resistant, non-combustible mineral wool product installed within the stud bays of a twin 90mm timber frame, lined with 9mm Villaboard on both sides. Up to 18% more compact than traditional common plasterboard shaftliner wall systems, it delivers significant increases in usable living space and increased land yield — making it the preferred choice for developers working on townhouses, terraces, and multi-occupancy projects across Australia.
Key Benefits for Builders & Developers
Fire Resistant — FRL 60/60/60 Certified
CodeMark certified FRL 60/60/60 — HardieFire™ mineral wool will not contribute to the spread of fire. Accepted Australia-wide.
Acoustic Performance — NCC Compliant
Twin 90mm frame with HardieFire™ insulation meets NCC sound transmission requirements — delivering a quiet, safe home between tenancies.
High Performance — 30% Faster to Install
A high performance, efficient lightweight wall system — installs up to 30% faster than comparable fire and acoustic rated wall systems.
Up to 18% More Compact — More Usable Living Space
Up to 18% more compact than plasterboard shaftliner systems — delivering significant increases in usable living space and land yield.
Weather Resistant and Resistant to Moisture Damage
HardieFire™ fibre cement offers dimensional stability — weather resistant and resistant to moisture damage across all Australian environments.
Resistant to Termite Damage— Low Maintenance
Villaboard lining is resistant to termite damage and low maintenance — a durable long-term specification for builders and homeowners.
Australian Made — Backed by Hardie™ Smart Wall Systems Component Warranty
Australian made components covered by the Hardie™ Smart Wall Systems Component Warranty — built for confidence and long-term performance.
Who Is This System For?
Volume Builders & Developers
Working on townhouses, terraces, and multi-residential developments requiring NCC compliant separating walls
Building certifiers
reviewing wall system compliance documentation for residential developments
Architects & Building Certifiers
Specifying fire and acoustic rated common wall solutions for Class 1 and 10A timber-framed buildings
Specifiers and distributors
Sourcing CodeMark certified fire and acoustic wall assemblies for the Australian market
Homeowners and owner builders
Undertaking semi-detached construction who need a proven, certified wall solution
System Specifications at a Glance
| Fire Resistance Level | 60/60/60 minutes |
| Frame Type | Twin 90mm timber frame |
| Cavity Separation | 30mm |
| Insulation | 60mm HardieFire™ Rock-wool |
| Lining | 9mm Villaboard both sides |
| Building Class | Class 1 and 10A |
| Certification | CodeMark Certified |
| Installation Speed | Up to 30% faster than comparable systems |
The Full HardieSmart Fire and Acoustic Wall System Range
Fire and acoustic rated common wall solution for Class 1 & 10A timber-framed buildings. CodeMark certified FRL 60/60/60. Up to 30% faster to install and 18% more compact than plasterboard shaftliner systems.
Dual-certified fire and acoustic rated common wall solution with independently verified acoustic performance by Renzo Tonin Acoustics — for projects where acoustic certification documentation is required.
Fire and acoustic rated boundary wall for Class 1 & 10A buildings. Up to 45% more compact than brick veneer — gaining 1.25m² per 10 lineal metres. Suitable for bushfire zone areas up to BAL-FZ.
High performance fire-rated wall for cantilevering balconies and ground wall extensions on tight spaces and narrow sites. Wall thickness starting as low as 102mm — delivering significant savings in outdoor living space.
Fire and acoustic rated dual boundary wall solution for multi-occupancy projects. Enables construction of all dwellings independently — improved business cash flow and increased internal liveable space for the same block of land.
GET A FREE QUOTE
How It Works
Fill out your contact information
Select the project stage
Upload your plans
Upload your energy report
FAQs
What fire rating does the Hardie Fire Intertenancy Wall System achieve?
How much more compact is it compared to plasterboard shaftliner systems?
The Hardie Fire Intertenancy Wall System is up to 18% more compact than traditional common plasterboard shaftliner wall systems. This delivers significant increases in usable living space and increased land yield — on a standard townhouse development, the space gains across multiple dwellings are commercially meaningful.