hardie smart boundary wall system

Australia’s Most Compact Fire Rated Boundary Wall Solution for Class 1 and 10A Timber Frame Buildings

60/60/60 Fire Resistance
Level
0% Faster to
Install
0% More
Compact
0+ 5-Star
Reviews

Twin 90 MM

Timber Frame

30 MM Cavity

Separation

60mm HardieFire™

Insulation

9mm Villaboard

Timber Frame

Class 1 & 10A

Building Type

What Is the Hardie Smart Boundary Wall System?

The Hardie Smart Boundary Wall System is a fire and acoustic rated boundary wall solution for Class 1 and 10A timber frame boundary wall applications — a compact boundary wall solution up to 45% more compact than a 230mm thick brick veneer wall. For every 10 lineal metres, builders gain 1.25m² of floor space — a significant saving in usable land area while maximising property value across every development.

Under NCC Vol 2 Section 3.7.1, external walls in close proximity to the boundary must achieve a certified fire resistance level. The system uses a 90mm timber frame with 90x45mm timber studs, HardieFire 60mm insulation (insulation R-value 1.7, mineral wool density 80 kg/m³), 6mm external cladding, James Hardie internal lining, and HardieWrap weather barrier — delivering a fire rated boundary wall at just 102mm minimum wall thickness. No Gap Insulation is an authorised Australian supplier of HardieFire insulation for this system.

System Specifications at a Glance

Fire Resistance Level FRL 60/60/60 (from the outside)
Acoustic Rating Rw 47–48
Total R-value 1.59 to 1.93 m²k/W
Minimum Wall Thickness 102mm
Frame Type 90mm timber frame — 90x45mm studs
Insulation HardieFire™ 60mm — R-value 1.7
Insulation Density 80 kg/m³
External Face 6mm James Hardie™ fibre cement
Weather Barrier HardieWrap™ Weather Barrier
Service Cavity 30mm
Stud Spacing 600mm maximum
Nogging Spacing 1200mm maximum
Bushfire Rating Suitable up to BAL-FZ
Bracing Capacity 4 to 10 kN/m (ULS)
Certification CodeMark Certificate CM20135

Key Features and Benefits

FRL 60/60/60 — CodeMark Certified

Assessed FRL from the outside by CSIRO fire assessment and BRANZ assessment per AS 1530.4. CodeMark certificate CM20135 accepted by certifiers as a NCC compliance wall without additional sign-off in most standard applications.

Up to 45% More Compact Than Brick

At 102mm minimum wall thickness — 45% more compact than a 230mm thick brick veneer wall. For every 10 lineal metres, builders gain 1.25m² of floor space — a significant saving in usable land area while maximising property value.

Suitable for Bushfire Zone Areas Up to BAL-FZ

Suitable for bushfire zone areas up to BAL-FZ — including flame zone and bushfire prone area wall applications — delivering certified facade fire compliance without the bulk of masonry alternatives.

Acoustic Rated Wall

Achieves a Rw rating of Rw 47–48 — providing meaningful sound attenuation for residential boundary wall and allotment boundary applications requiring dual fire and acoustic performance.

Total R-value 1.59 to 1.93 m²k/W

Certified total R-value of 1.59 to 1.93 m²k/W — assessed per AS/NZS 4859.2:2018 accounting for thermal bridging. Suitable for energy efficiency assessment under NCC 2019 Part 3.12.

30mm Service Cavity — Electrical and Plumbing Within the Wall

The 30mm service cavity allows electrical cables in service cavity, plumbing pipes service cavity, and 20mm plumbing pipe service cavity without compromising the fire resistance level. Bostik FireBan One required at all penetrations to maintain the 60 minute fire rating.

Why Choose Hardie™ Fibre Cement?

The 6mm fibre cement sheet used as 6mm external cladding in this system is a genuine James Hardie fibre cement product — engineered to deliver a unique combination of performance properties that no other cladding material can match.

  • Modern Look
    Provides contemporary clean lines and pared-back aesthetics for homes with simple bold forms.
  • Weather Resistant
    Engineered for harsh Australian environments including coastal conditions and wind-driven rain.
  • Fire Resistant
    Will not contribute to the spread of fire within or across the assembly — essential for boundary wall applications.
  • Resistant to Moisture Damage
    Offers dimensional stability — resisting swelling movement and warping over time.
  • Flexible Colour
    Pre-primed and pre-sealed — ready to paint in any colour to suit any architectural style.
  • Low Maintenance
    Easy to clean and holds paint well over time — reducing ongoing maintenance costs for homeowners and builders.
  • Resistant to Termite Damage
    Stands up to termite attack where timber-based cladding alternatives are vulnerable to infestation.
  • Australian Made
    Choose James Hardie fibre cement to support local manufacturing and ensure reliable supply for every project.

Who Should Specify This System?

Volume builders and developers

Working on townhouses terraces and detached buildings requiring NCC compliant boundary walls

Architects and building designers

Specifying a fire rated boundary wall for class 1 building boundary wall and class 10a building boundary wall applications

Building certifiers and surveyors

CodeMark certificate CM20135 and test reports available from James Hardie Engineering Solutions on 13 11 03

Developers on infill sites

Requiring a compact boundary wall solution to maximise 1.25m² of floor space gains per 10 lineal metres

Builders in bushfire prone areas

Requiring a bushfire prone area wall rated up to BAL-FZ

Duplex build

Developers requiring a zero lot boundary wall on tight urban lots

The Full HardieSmart Fire and Acoustic Wall System Range

01 Fire & Acoustic Wall
Hardie Fire Intertenancy Wall System

Fire and acoustic rated common wall solution for Class 1 & 10A timber-framed buildings. CodeMark certified FRL 60/60/60. Up to 30% faster to install and 18% more compact than plasterboard shaftliner systems.

FRL 60/60/60 Class 1 & 10A CodeMark 30% Faster
Learn More →
02 Dual Certified System
HardieSmart Fire & Acoustic Between Tenancies

Dual-certified fire and acoustic rated common wall solution with independently verified acoustic performance by Renzo Tonin Acoustics — for projects where acoustic certification documentation is required.

FRL 60/60/60 Acoustic Verified Renzo Tonin CodeMark
Learn More →
03 You Are Here
HardieSmart Boundary Wall System

Fire and acoustic rated boundary wall for Class 1 & 10A buildings. Up to 45% more compact than brick veneer — gaining 1.25m² per 10 lineal metres. Suitable for bushfire zone areas up to BAL-FZ.

45% More Compact BAL-FZ Rated Class 1 & 10A
✓ Current Page
04 Compact Fire Wall
Hardie™ Blade Wall System

High performance fire-rated wall for cantilevering balconies and ground wall extensions on tight spaces and narrow sites. Wall thickness starting as low as 102mm — delivering significant savings in outdoor living space.

From 102mm Tight Spaces Balconies
05 Dual Boundary Solution
Hardie™ Smart ZeroLot™ Wall System

Fire and acoustic rated dual boundary wall solution for multi-occupancy projects. Enables construction of all dwellings independently — improved business cash flow and increased internal liveable space for the same block of land.

Dual Boundary Independent Build Land Yield

Design Considerations and Construction Details

Boundary Setback and NCC Requirements

Required under NCC Vol 2 Section 3.7.1 for buildings within 900mm of boundary and walls on the allotment boundary. Boundary setback 500mm minimum applies in many councils. All design must comply with the National Construction Code.

Construction Details

Junctions and Connections Slab detail boundary wall and base detail slab require damp proof course and corrosion resistant metal flashing. Roof junction boundary wall requires fire resisting mineral wool to maintain FRL. Window detail fire rated wall requires appropriate flashing. Continuous sacrificial timber block (char blocking) must be sacrificial timber 45mm minimum.

Fastener Type Limitation

Minimum Class 3 fastener required in standard applications. Class 4 fastener coastal mandatory within 1km of salt spray environment locations. All corrosion resistant fastener selections must follow fastener type limitation guidelines.

Component Substitution

Component substitution is not permitted — HardieWrap weather barrier, HardieFire insulation, and 6mm external cladding must be used as specified. Full James Hardie warranty applies only when genuine James Hardie external cladding is used throughout.

GET A FREE QUOTE

e.g. Home is 30 years old, front is a lot colder than the back part of the house

How It Works

1

Fill out your contact information

2

Select the project stage

3

Upload your plans

4

Upload your energy report

FAQs

The system achieves FRL 60/60/60 assessed FRL from the outside — the direction of fire exposure for wall near property boundary applications. This is verified through CSIRO fire assessment and BRANZ assessment in accordance with AS 1530.4, with CodeMark certificate CM20135 accepted by certifiers across Australia.
The Hardie Smart Boundary Wall System is up to 45% more compact than a 230mm thick brick veneer wall. For every 10 lineal metres, builders gain up to 1.25m² of floor space — a significant saving in usable land area that directly contributes to maximising property value across the development.
Yes. The system is suitable for bushfire zone areas up to BAL-FZ — including flame zone applications — making it one of the most comprehensively rated bushfire prone area wall solutions available for timber frame boundary wall construction in Australia.
The Hardie Smart Boundary Wall System achieves a 102mm minimum wall thickness — significantly thinner than brick and AAC alternatives — while maintaining full NCC compliance wall performance for buildings within 900mm of boundary applications.
The system achieves an acoustic rated wall rating of Rw 47–48 — providing meaningful sound attenuation for residential boundary wall applications between properties.
In most standard applications, CodeMark certification — CodeMark certificate CM20135 — means certifiers accept the system without additional sign-off. For applications outside the scope of the design guide, contact James Hardie Engineering Solutions on 13 11 03.
No Gap Insulation stocks HardieFire insulation Australia-wide from the Epping VIC warehouse. Contact us on 03 8592 1900 or email sales@nogap.net.au for trade pricing and availability.