⚡ Part of the No Gap Group - Insulation ✦ Energy ✦ Interiors
⚡ 10,000+ Jobs Completed Annually
⚡ VEU Program Participant
⚡ EEC Corporate Member
⚡ Servicing Victoria & New South Wales
⚡ Upfront Pricing — No Hidden Fees. Ever.
⚡ Licensed & Insured Installers
⚡ 300+ Five-Star Google Reviews
⚡ Part of the No Gap Group - Insulation. Energy. Interiors
⚡ 10,000+ Jobs Completed Annually
⚡ VEU Program Participant
⚡ EEC Corporate Member
⚡ Servicing Victoria & New South Wales
⚡ Upfront Pricing — No Hidden Fees. Ever.
⚡ Licensed & Insured Installers
⚡ 300+ Five-Star Google Reviews

My Account

Book A Job

Hardie Smart Fire and Acoustic Between Tenancies

Australia’s Only Dual-Certified Fire and Acoustic Rated Separating Wall Solution for Class 1 and 10A Timber Frame Buildings

60/60/60 Fire Resistance
Level
0% Faster to
Install
2-in-1 Fire &
Acoustic
0+ 5-Star
Reviews

Fire Resistance

FRL 60/60/60 — CodeMark Certified

Acoustic Performance

NCC Compliant — Renzo Tonin Verified

Single Assembly

Single Assembly

Fast Delivery

From Epping VIC — Australia Wide

What Is the Hardie Smart Fire and Acoustic Between Tenancies System?

The Hardie Smart Fire and Acoustic Between Tenancies system is a CodeMark certified (Certificate CM40390) fire and acoustic rated common wall solution — also known as a separating wall — designed for Class 1 and 10A timber frame buildings. A high performance, efficient lightweight wall system achieving FRL 60/60/60 minutes TWO WAY, Rw + Ctr >50, and a total R-value of R3.22 to R3.51 m²k/W — backed by the Hardie™ Smart Wall Systems Component Warranty.

The system uses a twin 90mm timber frame with 30mm cavity separation, 60mm Hardie™ Fire Insulation compressed 5mm into each stud bay, and 9mm Villaboard™ lining on both sides — with a 30mm service cavity allowing cables and conduits up to 20mm diameter without compromising the certified FRL. Fire performance is assessed by CSIRO and BRANZ per AS1530.4 (FCO-3222-Rev L). Acoustic modelling by Renzo Tonin Acoustics Pty Ltd is based on CSIRO and RMIT testing per AS1191. No Gap Insulation is an authorised Australian supplier of 60mm Hardie™ Fire Insulation for this system.

Why Builders Specify This System

01

FRL 60/60/60 — CodeMark Certified

Assessed by CSIRO per AS1530.4 to meet NCC Volume Two H3D2. CodeMark Certificate CM40390 accepted by certifiers Australia-wide without additional sign-off in standard Class 1 and 10A applications.

02

Acoustic Rating Rw + Ctr >50 — Independently Verified

HSIW-1 achieves 60 Rw | 51 Rw+Ctr — exceeding the NCC Rw + Ctr >50 requirement. Verified by Renzo Tonin Acoustics Pty Ltd based on CSIRO and RMIT testing per AS1191.

03

Total R-value R3.22 to R3.51 m²k/W

Certified per AS/NZS 4859.2:2018 including thermal bridging. R3.51 at 600mm stud centres — suitable for NCC 2022 Vol 2 Part H6 energy efficiency compliance.

04

Bracing Performance 4.0 to 10 kN/m

4.0 kN/m standard fixing — up to 10 kN/m with anchor rods. Ultimate Limit State (ULS) figures certified by Cardno (NSW) Pty Ltd per AS1684.

04

30mm Service Cavity — Services Without Compromise

Electrical cables, plumbing conduits, and non-flammable refrigerant AC pipes up to 20mm diameter permitted within the service cavity without compromising the certified FRL.

04

Wall Footprint of Only 228mm

At 228mm total width, gains in usable living space and land yield are delivered over brick and plasterboard shaftliner alternatives — maximising return on every development.

04

Hardie™ Smart Wall Systems Component Warranty

Genuine 60mm Hardie™ Fire Insulation (Part No 305902, 305903, 305909) supplied through authorised channels — warranty validity guaranteed on every No Gap order.

How It Compares to the Standard Intertenancy System

Factor Hardie Fire
Intertenancy
Hardie Smart Fire & Acoustic
Fire Compliance ✓ FRL 60/60/60 ✓ FRL 60/60/60
Acoustic Compliance Standard NCC ✓ Independently Verified
Acoustic Assessor — ✓ Renzo Tonin Acoustics
Best For Standard fire separation ✓ Where verified acoustics required
Certification ✓ CodeMark ✓ CodeMark

Who Should Specify This System?

The Full HardieSmart Fire and Acoustic Wall System Range

01 Fire & Acoustic Wall
Hardie Fire Intertenancy Wall System

Fire and acoustic rated common wall solution for Class 1 & 10A timber-framed buildings. CodeMark certified FRL 60/60/60. Up to 30% faster to install and 18% more compact than plasterboard shaftliner systems.

FRL 60/60/60 Class 1 & 10A CodeMark 30% Faster
Learn More →
02 You Are Here
HardieSmart Fire & Acoustic Between Tenancies

Dual-certified fire and acoustic rated common wall solution with independently verified acoustic performance by Renzo Tonin Acoustics — for projects where acoustic certification documentation is required.

FRL 60/60/60 Acoustic Verified Renzo Tonin CodeMark
✓ Current Page
03 Boundary Wall Solution
HardieSmart Boundary Wall System

Fire and acoustic rated boundary wall for Class 1 & 10A buildings. Up to 45% more compact than brick veneer — gaining 1.25m² per 10 lineal metres. Suitable for bushfire zone areas up to BAL-FZ.

45% More Compact BAL-FZ Rated Class 1 & 10A
Learn More →
04 Compact Fire Wall
Hardie™ Blade Wall System

High performance fire-rated wall for cantilevering balconies and ground wall extensions on tight spaces and narrow sites. Wall thickness starting as low as 102mm — delivering significant savings in outdoor living space.

From 102mm Tight Spaces Balconies
05 Dual Boundary Solution
Hardie™ Smart ZeroLot™ Wall System

Fire and acoustic rated dual boundary wall solution for multi-occupancy projects. Enables construction of all dwellings independently — improved business cash flow and increased internal liveable space for the same block of land.

Dual Boundary Independent Build Land Yield

System Specifications at a Glance

Fire Resistance Level 60/60/60 minutes
Frame Type Twin 90mm timber frame
Cavity Separation 30mm
Insulation 60mm HardieFire™ Rock-wool
Lining 9mm Villaboard both sides
Building Class Class 1 and 10A
Application Common walls between tenancies
Acoustic Verification Renzo Tonin Acoustics
Certification CodeMark Certified
Installation Speed Up to 30% faster than comparable systems

GET A FREE QUOTE

e.g. Home is 30 years old, front is a lot colder than the back part of the house

How It Works

1

Fill out your contact information

2

Select the project stage

3

Upload your plans

4

Upload your energy report

FAQs

The standard HSIW-1 configuration achieves 60 Rw | 51 Rw+Ctr per wall — exceeding the NCC requirement of Rw + Ctr >50 for separating walls between tenancies in Class 1 buildings. Higher acoustic ratings are available through HSIW-2 (63 Rw | 54 Rw+Ctr) and HSIW-3 (65 Rw | 57 Rw+Ctr) configurations.

The system carries CodeMark Certificate CM40390. Certifiers and surveyors can request this certificate and relevant test reports from James Hardie’s Engineering Solutions team on 13 11 03.

The certified total R-value is R3.22 to R3.51 m²k/W depending on stud spacing, independently assessed in accordance with AS/NZS 4859.2:2018. At 600mm stud centres the total R-value is R3.51 m²k/W (winter). These values are suitable for NCC 2022 energy efficiency compliance under Part H6.

FRL 60/60/60 minutes TWO WAY — assessed by the CSIRO Division of Building Construction and Engineering and BRANZ in accordance with AS1530.4 (FCO-3222-Rev L).

Yes. Electrical cables and plumbing conduits up to 20mm diameter can be run in the 30mm service cavity between the insulation and the lining. Air-conditioning pipes carrying non-flammable refrigerants up to 20mm outside diameter are also permitted.

In most standard Class 1 and 10A applications, CodeMark Certificate CM40390 is accepted by building certifiers without additional engineering sign-off. For applications outside the scope of the Design Guide, contact James Hardie’s Engineering Solutions team on 13 11 03.

All three configurations achieve FRL 60/60/60 and Rw + Ctr >50. HSIW-1 uses 9mm Villaboard™ only and achieves 60 Rw | 51 Rw+Ctr. HSIW-2 adds 10mm plasterboard and achieves 63 Rw | 54 Rw+Ctr. HSIW-3 uses both 9mm Villaboard™ and 10mm plasterboard to achieve 65 Rw | 57 Rw+Ctr — the highest acoustic rating in the range.

No Gap Insulation stocks all three standard pack sizes (Part No 305902, 305903, 305909) and delivers Australia-wide from the Epping VIC warehouse. Contact us on 03 8592 1900 or email sales@nogap.net.au for trade pricing and availability.